NOVUM analyzes real operational data from battery storage systems and assesses anomalous system behaviour from a technical perspective. This helps narrow down potential causes of deviations and performance losses and identify well-founded measures for continued operation.

Operational data analysis of a battery storage system

Operational Data Analysis

When a battery storage system operates differently than planned

Battery storage systems are planned based on specifications, warranty metrics, and manufacturer claims. However, only real-world operation reveals how the system actually performs under varying conditions.

A key focus at NOVUM is therefore system comparison prior to purchasing a storage asset. As part of supplier qualification, we analyze operational data from storage systems across various manufacturers. In doing so, we examine software functionalities, state of charge determination, balancing, variations in cell behavior, and indications of structural design flaws. This enables clients to factor technical differences and their potential impact on profitability into their system selection.

Deviating charge and discharge profiles, declining usable capacity, abrupt changes in state of charge (SoC), anomalous temperature patterns, or recurring power curtailments quickly raise critical questions. Not every anomaly is critical. However, relevant deviations require a sound technical contextualization.

For existing storage facilities, NOVUM investigates why the system is not performing as intended. The key is understanding the potential root cause of a deviation: Is it rooted in the operating strategy, parameterization, data quality, system design, or the behavior of individual components?

NOVUM contextualizes operational data in technical context

NOVUM analyzes time series data, operating profiles, and system responses in a manufacturer-independent manner backed by deep battery analytics expertise. Our battery experts do not just look at individual measured values; they investigate how parameters and events interact and determine the technical significance of identifiable patterns.

The conclusive validity depends on the scope, quality, and resolution of the available data. In this way, complex operational data is transformed into actionable insights for system selection and supplier qualification, as well as for optimizations, service deployments, manufacturer communications, or further technical investigations.

Better contextualization

You understand how the storage system responds to different operating strategies and environmental conditions.

Clearer correlations

You recognize correlations between state of charge, voltage, temperature, power, and availability.

More targeted measures

You narrow down potential causes and prioritize optimizations, service deployments, or further testing.

Identifying causes based on operational data

NOVUM analyzes operational data down to the cell level, identifies correlations between anomalies and events, and narrows down possible causes. The operational data analysis includes the following steps:

We align key objectives, relevant timeframes, known anomalies, and available data sources with you.

NOVUM verifies that operational data is complete, temporally consistent, of sufficient resolution and plausible. Any limitations are taken into account in the evaluation.

Our battery experts analyze relevant parameters, system responses, and recurring patterns. In doing so, they examine causes, effects, and correlations.

We document the results, narrow down possible causes, and recommend specific next steps, such as optimizations, service deployments, manufacturer clarifications, or further testing.

Tim Wranika

Tim Wranika

Consultant

What do your battery storage operational data reveal?

NOVUM supports you in technically contextualizing operational data, understanding potential causes, and deriving concrete next steps.

Get in touch

Storage Guard

BESS monitoring beyond the BMS

Conventional Battery Management Systems (BMS) and supervisory control systems (SCADA) provide operational data and reactive alerts. Storage Guard goes further: It analyzes technical anomalies in a manufacturer-independent manner down to the cell level and makes safety- and performance-relevant deviations visible. AI-powered algorithms detect patterns, while NOVUM battery experts contextualize their technical significance.

This creates a solid foundation for continuously evaluating and enhancing the safety, revenues, and lifespan of battery storage systems.

NOVUM News

Discover more
Latest news, insights, and updates from NOVUM and the battery storage sector
Fünf blaue Batteriezellen unterschiedlicher Baugröße im direkten Größenvergleich in aufsteigender Reihenfolge.
Insights

Large-format battery cells in BESS: Gaining ground in the market and put to the test at NOVUM

Up to 6.9 MWh in a single standard container: Large-format LFP cells exceeding 500 Ah are challenging the incumbent 314 Ah standard cells for market dominance. The value proposition sounds promising: they can reduce component counts, increase energy density at the system level, and lower initial integration costs. [1] However, this leap in scale raises several physical questions, as increasing dimensions escalate requirements for cooling, fire safety, and degradation control. Because we at NOVUM are already analyzing these new large-format cells in our quality assessments, we checked in with our battery experts: How much do we know about their design, behavior, and safety, what critical factors must be considered, and what does this mean for BESS procurement?

Commissioning is only the beginning
Insights

Commissioning is only the beginning

Utility-scale battery energy storage systems (BESS) are expected to deliver reliable performance over many years. Two European examples highlighted in pv magazine ESS News demonstrate just how closely long-term revenues are tied to technical obligations. For investors and operators, factoring long-term performance trends into account right from the planning stage is therefore essential.

Björn Groß (ESG) steht vor einem geöffneten Batteriegroßspeicher mit sichtbaren Batteriemodulen und Racks.
Customer & Partner

Driving new energy systems with speed, courage, and pragmatism

With his company Energiesysteme Groß (ESG), Björn Groß built the first utility-scale battery energy storage system (BESS) in the Kassel region. In our interview, he revealed that he generally takes a "disruptive" approach. The solar industry is his home, and the whole world of renewable energy systems is his new domain. Bjön talks about his initial experiences with utility-scale BESS procurement, his motivations, and his future goals.

Frequently Asked Questions

FAQ

Find answers to the most common questions regarding battery storage systems, operational data, storage requirements, and services.

An operational data analysis reveals how a BESS behaves in real-world operation at the cell, module, and system levels. NOVUM analyzes time series data and correlations to identify the causes and effects of technical anomalies. This makes it clear whether issues such as elevated temperatures, balancing problems, or inaccurate state of charge determination are impairing the performance, lifespan, and revenues of the battery storage system.

An operational data analysis is valuable both prior to procurement and during ongoing BESS operation. As part of supplier qualification, data from an identical system already in operation can help better assess technical vulnerabilities, performance capabilities, and financial risks prior to investment. This also supports bankability evaluations and financing. During active operation, the analysis reveals the current health of the battery storage system and helps identify causes for deviations in capacity, state of charge, or performance.

Operational data analysis requires time series data from the battery storage system, such as data from the BMS, EMS, or SCADA systems. Depending on the specific requirements, system specifications, error logs, event logs, and operational profiles may also be relevant. NOVUM first audits the available data foundation and then defines which evaluations can be performed on a sound technical basis.

NOVUM analyzes operational data to narrow down potential causes of technical anomalies and contextualize them technically. In doing so, correlations between cells, modules, operating states, and events are examined. Whether a cause can be uniquely determined depends on the quality, resolution, and completeness of the available data.