Understand what happens
inside battery cells.
NOVUM’s cell quality analysis provides detailed insights into the condition and ageing of selected battery cells. Our battery experts examine the cells and assess technical anomalies. This reveals potential weaknesses that operational data, data sheets and standard documentation alone cannot explain.

Cell Quality Analysis
Anomalies in battery storage systems can originate at the cell level
The quality and design of battery cells significantly impact the safety, performance, and lifespan of a battery storage system. However, manufacturing differences and potential vulnerabilities are barely discernible from the outside.
Data sheets, certificates, and factory audits provide valuable information. However, they do not always answer whether a specific cell type aligns with the planned operating profile and the financial goals of the project. This creates uncertainty for operators, investors, and project developers: What performance and lifespan can be expected under the intended operating conditions? A targeted evaluation of selected cells prior to purchasing a storage system helps assess their quality and suitability for the project.
NOVUM provides manufacturer-independent evaluation of battery cells for your storage project
NOVUM examines selected battery cells prior to purchase and evaluates their quality and suitability in a manufacturer-independent manner. Our battery experts assess manufacturing quality, potential safety-relevant anomalies, and whether the cells can achieve the specifications outlined in the data sheet under the intended operating conditions.
To achieve this, we align the specific cell design with your planned operating profile and evaluate expected performance and lifespan. The results highlight which differences between the evaluated cell types are relevant to your business case. This allows you to base your purchasing decision on an independent, project-specific assessment.
Clear cell condition
You identify signs of aging, deviations, and potential vulnerabilities in the evaluated cells.
Expert evaluation
Experienced battery experts contextualize the results and recommend appropriate next steps.
More informed assessment
You can systematically plan further testing and manufacturer clarifications while assessing the conclusive validity of the cell samples.
We align key questions, known anomalies, and the technical context with you.
NOVUM provides support in selecting suitable battery cells. In doing so, we take into account their origin, operating conditions, and the conclusive validity of the available samples.
We analyze the cell samples according to cell type, condition, and agreed requirements.
Our battery experts contextualize anomalies and signs of aging. The final report documents insights, limitations regarding conclusive validity, and recommended next steps.
Storage Guard
BESS monitoring beyond the BMS
Conventional Battery Management Systems (BMS) and supervisory control systems (SCADA) provide operational data and reactive alerts. Storage Guard goes further: It analyzes technical anomalies in a manufacturer-independent manner down to the cell level and makes safety- and performance-relevant deviations visible. AI-powered algorithms detect patterns, while NOVUM battery experts contextualize their technical significance.
This creates a solid foundation for continuously evaluating and enhancing the safety, revenues, and lifespan of battery storage systems.
NOVUM News

Large-format battery cells in BESS: Gaining ground in the market and put to the test at NOVUM
Up to 6.9 MWh in a single standard container: Large-format LFP cells exceeding 500 Ah are challenging the incumbent 314 Ah standard cells for market dominance. The value proposition sounds promising: they can reduce component counts, increase energy density at the system level, and lower initial integration costs. [1] However, this leap in scale raises several physical questions, as increasing dimensions escalate requirements for cooling, fire safety, and degradation control. Because we at NOVUM are already analyzing these new large-format cells in our quality assessments, we checked in with our battery experts: How much do we know about their design, behavior, and safety, what critical factors must be considered, and what does this mean for BESS procurement?

Commissioning is only the beginning
Utility-scale battery energy storage systems (BESS) are expected to deliver reliable performance over many years. Two European examples highlighted in pv magazine ESS News demonstrate just how closely long-term revenues are tied to technical obligations. For investors and operators, factoring long-term performance trends into account right from the planning stage is therefore essential.

Driving new energy systems with speed, courage, and pragmatism
With his company Energiesysteme Groß (ESG), Björn Groß built the first utility-scale battery energy storage system (BESS) in the Kassel region. In our interview, he revealed that he generally takes a "disruptive" approach. The solar industry is his home, and the whole world of renewable energy systems is his new domain. Bjön talks about his initial experiences with utility-scale BESS procurement, his motivations, and his future goals.